On the Console
page you can configure keys and TFT views.
To configure an element, select it by clicking in the Console View
area. Its options are shown in the area to the right of the Console View
area.
option | description |
---|---|
Default View | In this list, all available default TFT views are shown. Select a default view from the list. (For differences between the default views see Default views table below) |
Show System Messages | Select the check box in front of the system message to enable it on the TFT/Touch Display. |
option | description |
---|---|
Number | Shows the generated number of the selected key: <name of fader module>.Key<key number on this module> |
Function | Shows the assigned key function. To change the default key function of a key, follow these steps: 1. Select a key on the console view. 2. In the View menu, select Key Functions . The Key Functions window opens.3. In the Key Functions window select a Key Function from the list and click Select . |
Label | Enter a name for the key. This name will be shown in the Console View and will be available for the label print feature. |
Colors | Depending on the selected key function, you can define here, with which color the key shall light up according to the lamp source. On is the color if the function is enabled, Off if the function is in inactive condition. For the last case, mostly the Off option is used, for example the key does not light up. Depending on the selected key function, you find also different names in the Lamp Source column, for example Standby , Available , Busy , Owned , Layer A , Layer B or the name of the selected lamp source . You can define the colors red and yellow. You can define flashing colors for the keys. Select the check box, in the Colors area. To change the logic source for a color, select an entry in the Lamp Source column and click Source . The Logic Sources window opens. In the Logic Sources window, select a logic source from the list and click Assign . |
Toggle Mode | Momentary - The function is enabled as long as the key is pressed.\\ Toggle - This key is stay put.\\ Timed Toggle - This key is stay put (short press) or spring return (long press). |
Press the Program
key, to send the PGM 1 bus audio signal to the Mon1 bus. When the Program
key is not active, the audio sources which is selected in the Selector
view on the TFT is sent to the Mon1
bus. To set the audio source for this Mon1
bus, follow these steps:
Selector
button. The Selector
view is shown.Selector
.Selector Sources
area, tap on the audio source that should be routed to the Mon1
bus.You can configure these keys as User Defined Key.
User defined:
(not assigned)
in the Lamp Source
column, you can either select the key itself as a source or select any source from the logic sources
window.Lamp Source
column to its new priority place.You can configure this key only as User Defined Key.
User defined:
(not assigned)
in the Lamp Source
column, you can either select the key itself as a source or select any source from the logic sources
window.Colors
area. Drag a row in the Lamp Source
column to its new priority place.In the following table, the differences between the default TFT views are shown.
view name | standard elements (Std) (PGM peak meter, CUE peak meter, 4 state indicators, navigation buttons, user name) | clock (Clk) | three additional peak meter for PGM 2, Aux 1, Aux 2 (3PM) | timer (Tmr) | sync status indicators |
---|---|---|---|---|---|
Std+Clk | X | X | X | ||
Std+Clk+3PM | X | X | X | X | |
Std+Clk+3PM+Tmr | X | X | X | X | |
Std-CUE+Clk | X (without CUE peak meter) | X | X | ||
Std+Tmr | X | X | |||
Std+3PM+Tmr | X | X | X | ||
Std | X | ||||
Std+Clk+Tmr | X | X | X |
X: the element is available in this view