Clock Logics are time-dependent logic sources. They become true at configured dates. To configure clock logics, in the project tree, select <Device>/Logic/Clock Logics
.
You can create up to 20 clock logics, which are active during user defined periods on any day of the week.
Note
If you want to use the clock logics, the device needs to be connected to a time server.
To create a new clock logic, click Add
. To delete a selected clock logic, click Remove
. Both functions are also available by right-click in the list.
To configure a clock logic, follow these steps:
Clock Logics
list, select a clock logic.Clock Logic
area, type an appropriate name in the Label
box. This label may be up to 10 digits long. Start time
box, type or select a time on which the clock logic becomes active (depending on selected days).Start days
check boxes to choose the days on which the Start time
activates the clock logic.End time
box, type or select a time on which the clock logic becomes inactive (depending on selected days).End days
check boxes to choose the days on which the End time
deactivates the clock logic.Examples:
In connection with the virtual key functions, you can trigger a key function for a determined point in time without having to push a real button.
Another example could be an automated activation/deactivation of a transmission line, in case the according studio is to be on air only for certain periods of time.