Firmware and Toolbox version 10.2 focus on evolving features and functionality introduced with XC3 & XD3 and version 10.1.
If an upgrade of your hardware is required and you are unsure how to handle this process, please contact your local DHD distributor - see List of DHD distributors.
License Serial
instead of Micro SD Serial
or SSD Serial
for licensing:License Serial
is shown in the System AppLicense Serial
will be the Wnnnnnnnnn
numberLicense Serial
will always be the serial of the factory installed MicroSD card –> the Cnnnnnnnnn
numberLicense Serial
will always be the serial of the factory installed SSD storage –> the Dnnnnnnnnn
numberLicense Serial
, licenses are always stored inside the DHD Core hardwareServices
menu
Important
The use of self signed certificates requires the user to initially accept a browser's security warning and/or to add an exception rule.
Note
No version 10.2 update available yet for 52-7567 AES67 or 52-7580/7585/7080B Dante modules.
These modules can be still be operated with their firmware/kernel version 10.0 or 10.1 without problems - even if the DHD Core is running on Version 10.2.
Important
Before upgrading to Version 10.2 ensure that the Core is updated to the latest Firmware 10.1 - minimum FW 10.1.14.
Note
The upgrade and further updates are now rolled out within a single DeviceOS
update package file.
This file can be applied like any other update file as knwon from before. The main difference is that all necessary software updates are now applied in one single step.
The file extension is:
xc3p
DeviceOS for XC3 Cores.xd3p
DeviceOS for XD3 Cores.
Important
The XD3 Update (Kernel & Firmware) takes approx. 2-3 minutes to finish. Do not switch off or restart the device during the update.</wrap>
As no major changes are introduced in Toolbox version 10.2, upgrading from version 10.1 to 10.2 should work by opening the existing project file within Toolbox 10.2 and checking if any messges are issued.
For a seamless transition, we recommend planning with enough spare time to convert your Toolbox project.
First of all, you need to have your Toolbox working at the latest Toolbox v10.1.x. If this condition is fulfilled, open your .dp10 project file with Toolbox v10.2.x.
Important
We strongly recommend to keep a copy of the original v10.1.x (.dp10
) project file.
You may receive some WARNING
messages in the Messages Section. Those messages inform you if your Toolbox project is using no longer supported hardware, if other problems occurred or if adjustments were done during conversion of the project. A double click on the message leads you to the hardware module or part of the configuration that is subject of the message.