Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
installation:voltage_drop [2016/11/07 15:53]
go [Voltage Drop at 15 A]
installation:voltage_drop [2016/12/21 15:39]
go [Voltage Drop]
Line 3: Line 3:
  
 <WRAP center round alert 60%> <WRAP center round alert 60%>
-**Warning**\\ ​ Maximum allowed voltage drop is 2,9V!+**Warning**\\ ​ Maximum allowed voltage drop is 2.9V!
 </​WRAP>​ </​WRAP>​
  
Line 100: Line 100:
 === Voltage Drop at 18 A === === Voltage Drop at 18 A ===
  
-^  Cable length\\ m  ^  Current\\ A  ^  Voltage drop\\ V \\ 2x 2.5 mm²  ^  Voltage drop\\ V \\ 2x 4 mm²  ^  Voltage drop\\ V \\ 2x 6 mm²  ^+^  Cable length\\ m  ^  Current\\ A  ^  Voltage drop\\ V \\ 2x 2.5 mm²\\ (2x AWG13) ​ ​^ ​ Voltage drop\\ V \\ 2x 4 mm² \\ (2x AWG11) ​ ​^ ​ Voltage drop\\ V \\ 2x 6 mm² \\ (2x AWG9)  ^
 |  1  |  18  |  0.26  |  0.16  |  0.11  | |  1  |  18  |  0.26  |  0.16  |  0.11  |
 |  3  |  18  |  0.8  |  0.49  |  0.32  | |  3  |  18  |  0.8  |  0.49  |  0.32  |