Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
installation:voltage_drop [2016/11/07 15:53] go [Voltage Drop at 15 A] |
installation:voltage_drop [2016/12/21 15:39] (current) go [Voltage Drop] |
||
---|---|---|---|
Line 3: | Line 3: | ||
<WRAP center round alert 60%> | <WRAP center round alert 60%> | ||
- | **Warning**\\ Maximum allowed voltage drop is 2,9V! | + | **Warning**\\ Maximum allowed voltage drop is 2.9V! |
</WRAP> | </WRAP> | ||
Line 100: | Line 100: | ||
=== Voltage Drop at 18 A === | === Voltage Drop at 18 A === | ||
- | ^ Cable length\\ m ^ Current\\ A ^ Voltage drop\\ V \\ 2x 2.5 mm² ^ Voltage drop\\ V \\ 2x 4 mm² ^ Voltage drop\\ V \\ 2x 6 mm² ^ | + | ^ Cable length\\ m ^ Current\\ A ^ Voltage drop\\ V \\ 2x 2.5 mm²\\ (2x AWG13) ^ Voltage drop\\ V \\ 2x 4 mm² \\ (2x AWG11) ^ Voltage drop\\ V \\ 2x 6 mm² \\ (2x AWG9) ^ |
| 1 | 18 | 0.26 | 0.16 | 0.11 | | | 1 | 18 | 0.26 | 0.16 | 0.11 | | ||
| 3 | 18 | 0.8 | 0.49 | 0.32 | | | 3 | 18 | 0.8 | 0.49 | 0.32 | |