Hardware

SXConfig Software - Hardware

On the Hardware page you can set which 52/SX modules are connected to your system.

In the Field Device name, enter a distinctive device name for this 52/SX mixing console.

Select Type:

  • In the left drop-down menu, select 52-1020 or 52-1024 depending on your fader modules.
  • In the right drop-down menu, select the number of faders.

Select your core type. (52-1810: Standard 52/XS Core; 52-1830: 52/XS Core with integrated Multi I/O)

  • Use MADI Module 52-7321: If your XS core is equipped with a MADI module 52-7321, please select this check box to enable the inputs and outputs for the I/O Settings tab.
  • Use Gigabit Audio 52-7391: If your XS core is equipped with a Gigabit Audio SFP Module, this enables the inputs and outputs in the I/O Settings tab. Gigabit Audio is useful e.g. to interlink with other DHD devices.
  • Use Dante module 52-7080: If your 52/XS core is equipped with a 52-7080 internal Dante module.

Tip
When using an older Core (52-1801 or 52-1804), they are not displayed by default. Go to Options>Configuration and select the Product Filter-Tab.

Activate show discontinued products. All Module types are now visible.

  • APC 8 (or APC 4 when using 52-1830 XS Core)|Select an I/O type or set the value to (none). Default is 52-1335.
  • APC 7 (not available when using 52-1830 XS Core)|Select an I/O type or set the value to (none). Default is 52-1335.
  • APC 6 (not available when using 52-1830 XS Core)|Select an I/O type or set the value to (none). Default is (none).

When you check Use 52-8511 PC TFT View Software, you can additionally assign a hardware module to APC 1. This is possible because you do not need an 52-4018 TFT module.

Important
52-8511 PC TFT View Software requires valid License!

Split: Shows a split version of the control modules in the preview. Flat: Shows the control modules build in a flat table installation frame instead of a console frame.