On the Synchronisation
tab, you can configure different synchronisation options for the device.
System Sample Rate
You can adjust the sample rate of a device to 48 kHz or 44.1 kHz.
Important
Even if the device works with external synchronisation, you have to set the correct sample frequency here, because the internal Quartz PLL can not adjust correctly to the external clock otherwise.
Synchronisation Sources
You can define two synchronisation sources on 52/XD2, 52/XD, 52/XC2 and 52/XC cores - Sync Source
and Sync Source 2
. On 52/XS and 52/XS2 cores you can configure only one sync source.
The source configured at Sync Source
is the primary synchronisation source. If this sync source fails, the system automatically changes to the source configured in the Sync Source 2
list. If the second sync source fails too, the system switches to the internal clock of 48 kHz or 44.1 kHz, depending on the selection above.
Sync sources can only be signals that are connected directly to the core. Cores with integrated MADI interface (52-7321, 52-7325, 52-1821 or 52-1825) can sync to that source. Otherwise an external BNC sync needs to be connected. The type of BNC source signal has to be selected on selecting source.
Also direct APC links or Gigabit Audio (GA) links between DSP Cores can be used as a sync source.
Available sync signal options
sync signal type | 52/XD2 cores | 52/XD cores | 52XC2 cores | 52/XC cores | 52/XS2 cores | 52/XS cores |
---|---|---|---|---|---|---|
Internal clock | Yes | Yes | Yes | Yes | Yes | Yes |
BNC: Wordclock | Yes | Yes | Yes | Yes | Yes | Yes |
BNC: AES11 | Yes | Yes | Yes | Yes | Yes | Yes |
BNC: PAL / NTSC | Yes | Yes | Yes | Yes | No | No |
BNC: HD Tri-Level | Yes | Yes | Yes | No | No | No |
MADI 1) | Yes | Yes | Yes | Yes | Yes | Yes |
GA 2) | Yes | Yes | Yes | Yes | Yes | Yes |
APC 3) | Yes | Yes | Yes | Yes | Yes | Yes |
AES67/Dante Core Extension Slot 4) | No | No | Yes | No | Yes | No |