Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
sx:xs_core [2016/05/30 16:51] marc |
sx:xs_core [2016/06/27 16:30] go [Recent XS2 Cores] |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | <- ^ sx:start|SXConfig ^ sx:fader_modules|Fader Modules -> | ||
======XS Core - DSP unit====== | ======XS Core - DSP unit====== | ||
- | |||
- | |||
The powerful 52/XS Core is an independent DSP system which does not require a PC for operation. There are no fans, hard discs or batteries inside the 52/XS Core and in the I/O boxes, allowing silent and low-maintenance operation directly in the studio. | The powerful 52/XS Core is an independent DSP system which does not require a PC for operation. There are no fans, hard discs or batteries inside the 52/XS Core and in the I/O boxes, allowing silent and low-maintenance operation directly in the studio. | ||
Line 38: | Line 37: | ||
|**Feature**|**52-1810**|**52-1830**| | |**Feature**|**52-1810**|**52-1830**| | ||
|support for redundant power supply|yes|yes| | |support for redundant power supply|yes|yes| | ||
- | |number of supported faders|12/16*|4| | + | |number of supported faders|12/16*|8| |
|number of supported I/O boxes|2/3%%**%%|1/2%%***%%| | |number of supported I/O boxes|2/3%%**%%|1/2%%***%%| | ||
|number of audio, power & control ports (APC)|8|4| | |number of audio, power & control ports (APC)|8|4| | ||
- | |serial interface for external control|yes|yes| | ||
|TCP/IP interface for external control|yes|yes| | |TCP/IP interface for external control|yes|yes| | ||
+ | |serial interface for external control|yes|yes| | ||
* 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801. | * 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801. | ||
Line 50: | Line 49: | ||
%%***%% Two I/O boxes are only possible if PC TFT View software is used instead of TFT Module. | %%***%% Two I/O boxes are only possible if PC TFT View software is used instead of TFT Module. | ||
- | ===== Outdated XS Cores ===== | ||
- | |||
- | In the following table the main differences between the 52-1801 and the 52-1804 are listed. | ||
- | |||
- | |**Feature**|**52-1801**|**52-1804**| | ||
- | |support for redundant power supply|yes|yes| | ||
- | |number of supported faders|12/16*|4| | ||
- | |number of supported I/O boxes|2/3%%**%%|1| | ||
- | |number of audio, power & control ports (APC)|8|4| | ||
- | |serial interface for external control|yes|yes| | ||
- | |TCP/IP interface for external control|yes|yes| | ||
- | |||
- | * 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801. | ||
- | |||