Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
sx:xs_core [2016/05/30 16:51]
marc
sx:xs_core [2016/06/27 16:30]
go [Recent XS2 Cores]
Line 1: Line 1:
 +<-  ^ sx:​start|SXConfig ^ sx:​fader_modules|Fader Modules ​ ->
 ======XS Core - DSP unit====== ======XS Core - DSP unit======
- 
- 
  
 The powerful 52/XS Core is an independent DSP system which does not require a PC for operation. There are no fans, hard discs or batteries inside the 52/XS Core and in the I/O boxes, allowing silent and low-maintenance operation directly in the studio. The powerful 52/XS Core is an independent DSP system which does not require a PC for operation. There are no fans, hard discs or batteries inside the 52/XS Core and in the I/O boxes, allowing silent and low-maintenance operation directly in the studio.
Line 38: Line 37:
 |**Feature**|**52-1810**|**52-1830**| |**Feature**|**52-1810**|**52-1830**|
 |support for redundant power supply|yes|yes| |support for redundant power supply|yes|yes|
-|number of supported faders|12/​16*|4|+|number of supported faders|12/​16*|8|
 |number of supported I/O boxes|2/​3%%**%%|1/​2%%***%%| |number of supported I/O boxes|2/​3%%**%%|1/​2%%***%%|
 |number of audio, power & control ports (APC)|8|4| |number of audio, power & control ports (APC)|8|4|
-|serial interface for external control|yes|yes| 
 |TCP/IP interface for external control|yes|yes| |TCP/IP interface for external control|yes|yes|
 +|serial interface for external control|yes|yes|
  
 * 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801. * 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801.
Line 50: Line 49:
 %%***%% Two I/O boxes are only possible if PC TFT View software is used instead of TFT Module. %%***%% Two I/O boxes are only possible if PC TFT View software is used instead of TFT Module.
  
-===== Outdated XS Cores ===== 
- 
-In the following table the main differences between the 52-1801 and the 52-1804 are listed. 
- 
-|**Feature**|**52-1801**|**52-1804**| 
-|support for redundant power supply|yes|yes| 
-|number of supported faders|12/​16*|4| 
-|number of supported I/O boxes|2/​3%%**%%|1| 
-|number of audio, power & control ports (APC)|8|4| 
-|serial interface for external control|yes|yes| 
-|TCP/IP interface for external control|yes|yes| 
- 
-* 16 fader (4 fader modules) are only possible if a maximum of two I/O boxes are used on the 52-1801. 
- 
-%%**%% Three I/O boxes are only possible if a maximum of 12 fader (3 fader modules) are used on the 52-1801.