Connecting modules to the 52/XS Core

The control modules and I/O boxes have to be connected to the APC ports of the 52/XS Cores 52-18xx. It is important to connect the peripheral modules to the correct APC port.

Important
Use always shielded CAT5 or CAT6 ethernet cables (at least S/UTP, F/UTP or SF/UTP) to connect these modules to the XS core.

Rear view of 52-1810
Rear view of 52-1830

In the following table you can find the assignment of the control modules, I/O boxes, DeviceLinks and TFT/Touch displays to the APC ports.

Name of the APC port52-181052-1830
APC 1TFT/touch display (52-4018)1)TFT/touch display (52-4018)2)
APC 2central control modul
(52-1010, 52-1011)
central control module
(52-1010, 52-1011)
APC 3fader module 1
(52-1020, 52-1021, 52-1024, 52-1025)
fader module 1
(52-1020, 52-1021, 52-1024, 52-1025)
APC 4fader module 2
(52-1020, 52-1021, 52-1024, 52-1025)
I/O box 1 / DeviceLink 1
APC 5fader module 3
(52-1020, 52-1021, 52-1024, 52-1025)
n. a.
APC 6fader module 4
(52-1020, 52-1021, 52-1024, 52-1025) / I/O box 3 / DeviceLink 3 3)
n. a.
APC 7I/O box 2 / DeviceLink 2n. a.
APC 8I/O box 1 / DeviceLink 1n. a.

Weblink
You find a PDF file with cabling examples in the 52/SX Download area at https://dhd.audio/product/521995g/.

Note
Make sure, that 52-1335 is selected at APC 8 and APC 7 at the Hardware page of the SXconfig software.

Example 12 Fader and 2 52/XS Multi-I/O Boxes

Important
Use minimum Firmware version 08-01-00 and SXConfig version 8-1-0-0 or the version on the CD supplied with the console, which may be a later version.

Cabling Example: 12 Fader and 2 52/XS Multi-I/O Boxes

Example 4 Fader and 1 52/XS2 I/O core

Important
Use minimum Firmware version 08-01-00 and SXConfig version 8-1-0-0 or the version on the CD supplied with the console, which may be a later version.

Cabling Example: 4 Fader and 1 52/XS2 I/O Core
1) , 2)
APC port 1 can be used as port for I/O box or DeviceLink if PC TFT View Software is used instead of TFT module.
3)
The APC port 6 is useable either for a fader module, an I/O box or an DeviceLink. Because of this, for example a 12 fader mixing console with three I/O boxes or a 16 fader mixing console with two I/O boxes are the maximum configurations for a 52/SX.