====== 52/MX Controller Cabling ====== | ====== 52/MX Controller Cabling ====== | ||
- | /* ===== 52-4060A controller ===== */ | + | ===== 52-4060A controller ===== |
+ | The analog audio connectors of the 52-4060 controllers are designed for internal use only: | ||
+ | |||
+ | * the output level is not compatible, less than standard line output levels of +4dBu or +6dBu | ||
+ | * the output has no short circuit protection, therefore a external use is not allowed | ||
+ | * THD+N of digital to analog converter is equivalent to the THD+N of 52-4527B and 52-4424B PFL / Talk back amplifier circuits & speaker, for headphone or monitoring use the THD+N would be too large | ||
+ | * the lower corner frequency response is limited to around 100 Hz, this is not useful for use with headphones or for monitoring | ||
+ | * internal 48V is on the same connector, misuse may damage the external device or the 52-4060 controller | ||
+ | * only 52-4527 and 52-4424 devices allowed to connect to the 52-4060 controller | ||
+ | |||
+ | |||
+ | -> use 52-7235A or 52-7224A or 52-1335A (or 52-7230A or 52-7222A or 52-7223A or 52-1330A/B) for connection of external analog equipment | ||
===== Controller ports on 52-4510A TFT display ===== | ===== Controller ports on 52-4510A TFT display ===== |