Timers
Select the Timers
tab to set the options for the available timers in the system.
You can use timers to show or set periods of times in which faders are open, to control other functions. (see Timer Running and Timer Reset for information)
In the Timers
area, all available timers are listed. You can neither add nor remove existing timers. Also, you can not change the sequence of the timers in the list. You can use a maximum of six timers per mixer.
The timers in the list have a fixed serial number Nr
and a Label
. You can not change the numbers. Select a timer from the Timers
list. In the Edit Timer
area, enter a name for this timer in the Label
box. This name may be up to 16 digits long. You can see the name Timers
list in the User Label
column.
For each timer, you can select a logic source for Start, Stop and Reset. For this, you can use any logic source, for example the keys of a control module.
Select a timer from the Timers
list. In the Edit Timer
area, select a logic from the list. Click Select
next to the Source
box. The Logic Sources
window opens. Select a logic source and click Assign
. Alternatively you can also double-click on the Logic source or use drag & drop.