Toolbox8 version 8.2 and firmware version 8.2 introduce a variety of new features and improvements.
Important
To find out if your hardware can be used with version 8.2, see Firmware Overview (Discontinued).
If an upgrade of your hardware is required, please contact your local DHD distributor - see List of DHD distributors.
New features include:
Toolbox8 v8.2.1:
Toolbox8 v8.2.2:
Toolbox8 v8.2.4
For a seamless transition, we recommend planning with enough spare time to convert your Toolbox8 project.
First of all, you need to have your Toolbox8 working at the latest Toolbox8 v8.1. If this condition is fulfilled, open your .dp8 project file with Toolbox8 v8.2.
Important
We strongly recommend to keep a copy of the original v8.1 (.dp8
) project file.
You may receive some WARNING
messages in the Messages Section. Those messages inform you if your Toolbox8 project is using no longer supported hardware. According to the messages here, refer to the steps below to upgrade your configuration. A double click on the message leads you to the hardware module that is subject of the message.
If you've been using Series 52 first generation core devices (52/XC/XD/XS), you need to upgrade to a current core device for using firmware version 8.2.
To find out if your core device is supported in this
version, see Firmware Overview (Discontinued).
If you have a Series 52 first generation core device (52/XC/XD/XS) and need to change the core type into 52/XC2/XD2/XS2 in you configuration:
Hardware Units
list on the leftChange Type
dropdown menu in the Unit Options
area to change the type of the core deviceSince 52-7300 and 52-7301 XC concentrators are no longer supported within firmware version 8.2, a change type functionality for discontinued concentrators was implemented. That way you don't have to delete your old concentrator from your Tollbox8 configuration and add a new one.
If you have a new Series 52 concentrator and need to change the type in you configuration:
Hardware Units
list on the leftChange Type
dropdown appears in the Unit Options
sectionChange type
dropdown menu will disappear when the type change to the new concentrator was successful.Module Name
, if it refers to the concentrator type
Important
A Toolbox8 v8.2 configuration can not be sent to the device if discontinued concentrators are used, that don't match the firmware requirements.
If you previously used a 52-1821 MADI Sub Module in your core or concentrator, you can use a 52-7321 or 52-7325 MADI SFP module as a replacement. Concentrators now support a MADI sub module on port SFP/GA 2.
To change the type of your 52-1821 MADI Sub Module, follow these steps:
<device> / I/O Overview
Select element
area, right-click the 52-1821 MADI Sub ModuleChange Type
and select your designated new MADI SFP module (see screenshot below)<device> / hardware
page and attach your new MADI SFP Module to the designated SFP Port in the Unit Ports
area.For instructions on how to configure Web Apps: Views, please see Views App (Web) - Quick Start.